READ_CTRLIO_INPUT_EX2

This structure provides real-time input signals from the robot controller, including digital inputs, analog inputs, switch states, safety inputs, and analog input modes. It aggregates various input signals for robot operation and diagnostics, specific to the EX2 version.

BYTE#

Field Name

Data Type

Value

Remarks

0

_iActualDI

unsigned char[NUM_DIGITAL_V3]

0x00~0x01

Digital inputs (on/off)

16

_fActualAI

float[NUM_ANALOG]

Analog inputs (numeric)

24

_iActualSW

unsigned char[NUM_SWITCH]

0x00~0x01

Switch inputs (incl. direct-teach)

27

_iActualSI

unsigned char[NUM_SAFETY_IN_V3]

0x00~0x01

Safety inputs

29

_iActualAT

unsigned char[NUM_ANALOG]

0x00~0x01

Analog input mode per channel (e.g., 0: V, 1: I)

Total size: 31 bytes

Defined in: DRFS.h

typedef struct _READ_CTRLIO_INPUT_EX2
{
    unsigned char _iActualDI[NUM_DIGITAL_V3];
    float         _fActualAI[NUM_ANALOG];
    unsigned char _iActualSW[NUM_SWITCH];
    unsigned char _iActualSI[NUM_SAFETY_IN_V3];
    unsigned char _iActualAT[NUM_ANALOG];
} READ_CTRLIO_INPUT_EX2, *LPREAD_CTRLIO_INPUT_EX2;