set_modbus_output (Manual Mode)

This section explains how to use set_modbus_output during Manual (Teach) operations to manually write values to PLC/inverter Modbus registers for on-site verification or parameter tuning.

Typical usage

  • Send coil ON/OFF commands (e.g., START/STOP, ENABLE).

  • Write setpoints or control words to Holding Registers (e.g., target speed, torque limit).

  • Validate device write behavior during communication setup before running Auto programs.

Note

  • Supported for register types COIL and HOLDING_REGISTER only.

  • For read-back verification, use get_modbus_input.

Example: Write coil and holding register outputs

#include "DRFLEx.h"
#include <thread>
#include <chrono>
#include <cstdio>
using namespace DRAFramework;

int main() {
    CDRFLEx drfl;
    // Preconditions:
    // - Connection established (open_connection)
    // - Manual (Teach) mode active
    // - Modbus symbols registered via add_modbus_signal()

    // 1) Register test symbols (simplified)
    drfl.add_modbus_signal("PLC_START",     "192.168.0.10", 502,
                           MODBUS_REGISTER_TYPE_COIL, 1, 0);
    drfl.add_modbus_signal("INV_SPEED_CMD", "192.168.0.10", 502,
                           MODBUS_REGISTER_TYPE_HOLDING_REGISTER, 100, 0, 1);

    // 2) Write target speed (example: 1500 = 15.00 Hz)
    bool ok_speed = drfl.set_modbus_output("INV_SPEED_CMD", 1500);

    // 3) Trigger start coil pulse
    bool ok_start = drfl.set_modbus_output("PLC_START", 1);
    std::this_thread::sleep_for(std::chrono::milliseconds(50));
    drfl.set_modbus_output("PLC_START", 0);

    // 4) Verify write success
    if (ok_speed && ok_start)
        std::printf("[Modbus] Output write successful.\n");
    else
        std::printf("[Modbus] Write failed. Check connection or tag name.\n");

    // 5) Cleanup
    drfl.del_modbus_signal("PLC_START");
    drfl.del_modbus_signal("INV_SPEED_CMD");
    return 0;
}

Tips

  • Avoid rapid consecutive writes; allow short delays (≥ 50 ms) between commands.

  • Always confirm device response using read-back or indicator bits.

  • Keep teaching environment clean by deleting all test symbols after use.