add_modbus_signal (Manual Mode)
This section explains how to use add_modbus_signal during Manual (Teach) operations to register external PLC / inverter Modbus points as symbolic tags for quick read/write tests in 3.2.3 Communication.
Typical usage
Map a PLC/inverter register (Coil / Discrete Input / Holding / Input Register) to a symbol name.
Verify READY/FAULT bits or write START/SPEED commands from a small test app during teaching.
Prepare a clean symbol set, then use get_modbus_input, set_modbus_output, and finally del_modbus_signal to clean up.
Note
Data width/sign/endian follow the device manual. Multi-word values may require device-specific handling.
Inspect the registered tags via query_modbus_data_list for debugging.
Example: Register and test READY (DI) + START (Coil) + SPEED (Holding Reg.)
#include "DRFLEx.h"
#include <thread>
#include <chrono>
#include <cstdio>
using namespace DRAFramework;
int main() {
CDRFLEx drfl;
// Preconditions:
// - Connection established (open_connection)
// - Manual (Teach) mode, servo/safety OK
// - External PLC/inverter reachable over the network
// 1) Register symbols (IP, port, type, address, default value, slave ID)
bool ok = true;
ok &= drfl.add_modbus_signal("PLC_READY", "192.168.0.10", 502,
MODBUS_REGISTER_TYPE_DISCRETE_INPUT, 0, 0);
ok &= drfl.add_modbus_signal("PLC_START", "192.168.0.10", 502,
MODBUS_REGISTER_TYPE_COIL, 1, 0);
ok &= drfl.add_modbus_signal("INV_SPEED_CMD", "192.168.0.10", 502,
MODBUS_REGISTER_TYPE_HOLDING_REGISTER, 100, 0, 1);
if (!ok) {
std::printf("[Modbus] Failed to register one or more symbols\n");
return -1;
}
// 2) Wait until external device is READY (max ~3s)
bool ready = false;
for (int i = 0; i < 30; ++i) {
// For DISCRETE_INPUT/INPUT_REGISTER types, read with get_modbus_input()
if (drfl.get_modbus_input("PLC_READY")) {
ready = true;
break;
}
std::this_thread::sleep_for(std::chrono::milliseconds(100));
}
std::printf("READY = %s\n", ready ? "ON" : "OFF");
if (!ready) goto CLEANUP;
// 3) Write a speed command (example: 1500 means 15.00 Hz if device uses 0.01 scaling)
drfl.set_modbus_output("INV_SPEED_CMD", 1500);
// 4) Issue START coil pulse
drfl.set_modbus_output("PLC_START", 1);
std::this_thread::sleep_for(std::chrono::milliseconds(50));
drfl.set_modbus_output("PLC_START", 0);
// Optional: Read back additional status via get_modbus_input("...") here
CLEANUP:
// 5) Always clean up test symbols
drfl.del_modbus_signal("PLC_READY");
drfl.del_modbus_signal("PLC_START");
drfl.del_modbus_signal("INV_SPEED_CMD");
return 0;
}
Tips
Double-check addressing (0/1-based), byte/word order, and scaling in the device manual.
Keep test tags namespaced (e.g.,
"TEST/PLC_READY") and always delete them after tests.If you see intermittent timeouts, add simple retry/timeout logic and inspect with query_modbus_data_list.