add_modbus_signal (Manual Mode)

This section explains how to use add_modbus_signal during Manual (Teach) operations to register external PLC / inverter Modbus points as symbolic tags for quick read/write tests in 3.2.3 Communication.

Typical usage

  • Map a PLC/inverter register (Coil / Discrete Input / Holding / Input Register) to a symbol name.

  • Verify READY/FAULT bits or write START/SPEED commands from a small test app during teaching.

  • Prepare a clean symbol set, then use get_modbus_input, set_modbus_output, and finally del_modbus_signal to clean up.

Note

  • Data width/sign/endian follow the device manual. Multi-word values may require device-specific handling.

  • Inspect the registered tags via query_modbus_data_list for debugging.

Example: Register and test READY (DI) + START (Coil) + SPEED (Holding Reg.)

#include "DRFLEx.h"
#include <thread>
#include <chrono>
#include <cstdio>
using namespace DRAFramework;

int main() {
    CDRFLEx drfl;
    // Preconditions:
    // - Connection established (open_connection)
    // - Manual (Teach) mode, servo/safety OK
    // - External PLC/inverter reachable over the network

    // 1) Register symbols (IP, port, type, address, default value, slave ID)
    bool ok = true;
    ok &= drfl.add_modbus_signal("PLC_READY",     "192.168.0.10", 502,
                                 MODBUS_REGISTER_TYPE_DISCRETE_INPUT, 0, 0);
    ok &= drfl.add_modbus_signal("PLC_START",     "192.168.0.10", 502,
                                 MODBUS_REGISTER_TYPE_COIL, 1, 0);
    ok &= drfl.add_modbus_signal("INV_SPEED_CMD", "192.168.0.10", 502,
                                 MODBUS_REGISTER_TYPE_HOLDING_REGISTER, 100, 0, 1);

    if (!ok) {
        std::printf("[Modbus] Failed to register one or more symbols\n");
        return -1;
    }

    // 2) Wait until external device is READY (max ~3s)
    bool ready = false;
    for (int i = 0; i < 30; ++i) {
        // For DISCRETE_INPUT/INPUT_REGISTER types, read with get_modbus_input()
        if (drfl.get_modbus_input("PLC_READY")) {
            ready = true;
            break;
        }
        std::this_thread::sleep_for(std::chrono::milliseconds(100));
    }
    std::printf("READY = %s\n", ready ? "ON" : "OFF");
    if (!ready) goto CLEANUP;

    // 3) Write a speed command (example: 1500 means 15.00 Hz if device uses 0.01 scaling)
    drfl.set_modbus_output("INV_SPEED_CMD", 1500);

    // 4) Issue START coil pulse
    drfl.set_modbus_output("PLC_START", 1);
    std::this_thread::sleep_for(std::chrono::milliseconds(50));
    drfl.set_modbus_output("PLC_START", 0);

    // Optional: Read back additional status via get_modbus_input("...") here

CLEANUP:
    // 5) Always clean up test symbols
    drfl.del_modbus_signal("PLC_READY");
    drfl.del_modbus_signal("PLC_START");
    drfl.del_modbus_signal("INV_SPEED_CMD");
    return 0;
}

Tips

  • Double-check addressing (0/1-based), byte/word order, and scaling in the device manual.

  • Keep test tags namespaced (e.g., "TEST/PLC_READY") and always delete them after tests.

  • If you see intermittent timeouts, add simple retry/timeout logic and inspect with query_modbus_data_list.