set_workpiece_weight

This function configures the weight and center of gravity (COG) of the currently mounted workpiece. It combines the tool parameters (set via set_tool) with the workpiece’s own weight and balance information to calculate the total end-effector dynamics used in control and safety calculations.

It is particularly useful for tasks where the workpiece mass changes dynamically or multiple payloads are handled.

Definition
DRFLEx.h within class CDRFLEx, public section (line 677)

bool set_workpiece_weight(
    float fWeight = 0.0,
    float fCog[3] = COG_DEFAULT,
    COG_REFERENCE eCogRef = COG_REFERENCE_TCP,
    ADD_UP eAddUp = ADD_UP_REPLACE,
    float fStartTime = -10000,
    float fTransitionTime = -10000
) {
    return _set_workpiece_weight(_rbtCtrl, fWeight, fCog, eCogRef, eAddUp, fStartTime, fTransitionTime);
};

Caution

  • Workpiece weight change is allowed only when both Collision Detection and TCP SLF Violation check are muted or disabled during Auto Mode.

  • In the current version, Collision Detection considers the function mute when Collision Sensitivity is overridden to 0 and TCP SLF considers the function mute when the TCP SLF Limit is overridden to the maximum. This override can be set using Collision Sensitivity Reduction Zone and Custom Zone.

  • Otherwise, trigger an SS1 protective stop unless the workpiece weight is set to zero.

  • If the robot stops due to an error and needs to be manually restored, place the robot in the desired position in the Recovery Mode and unload the workpiece through Servo On and I/O operation while the corresponding zones are activated in Auto Mode.

  • When changing the set tool weight, the workpiece weight is initialized to 0.

  • When using the set_tool and set_workpiece_weight in succession, you must use the wait function as much as transition_time between time. Otherwise, there may be errors in the weight change.

Parameter

Parameter Name

Data Type

Default Value

Description

fWeight

float

0.0

Workpiece weight in kilograms (kg).

fCog

float[3]

[0, 0, 0]

Center of gravity of the workpiece in millimeters [x, y, z].

eCogRef

COG_REFERNCE

COG_REFERENCE_TCP

Reference coordinate system for the COG.

eAddUp

ADD_UP

ADD_UP_REPLACE

Behavior when updating workpiece info
DR_REPLACE(0): Replace existing workpiece
DR_ADD(1): Add workpiece data
DR_REMOVE(2): Remove existing workpiece

fStartTime

float

-10000

Start time (in seconds) for the workpiece weight change.

fTransitionTime

float

-10000

Transition time (in seconds) for gradually applying weight change.

Return

Value

Description

0

Error — workpiece weight not applied

1

Success — weight and COG information successfully updated

Example

#include "DRFLEx.h"
using namespace DRAFramework;

int main() {
    CDRFLEx drfl;

    // Set safety mode to autonomous before changing payload info
    drfl.set_safety_mode(SAFETY_MODE_AUTONOMOUS, SAFETY_MODE_EVENT_NONE);

    // Apply new workpiece weight (2.5 kg) with COG at (0, 0, 50 mm)
    float fCog[3] = {0.f, 0.f, 50.f};
    drfl.set_workpiece_weight(2.5f, fCog);

    // Stop autonomous mode once weight setting is done
    drfl.set_safety_mode(SAFETY_MODE_AUTONOMOUS, SAFETY_MODE_EVENT_STOP);
}

This example demonstrates how to safely apply a new workpiece weight and COG configuration while switching to autonomous mode to ensure smooth transition without triggering safety stops.