query_modbus_data_list (Manual Mode)

This section explains how to use query_modbus_data_list during Manual (Teach) operations. This function retrieves the current list of Modbus signals (both inputs and outputs) registered in the controller. It allows operators to verify communication mappings, monitor connected devices, and debug Modbus I/O configurations during manual setup or testing.

Typical usage

  • Display all registered Modbus input/output channels during system commissioning.

  • Check whether a device (e.g., PLC, sensor, actuator) is properly linked to the Modbus network.

  • Validate signal names, data addresses, and values before running automatic sequences.

  • Use as a diagnostic tool when Modbus devices fail to respond or behave unexpectedly.

Note

  • The function provides read-only data; it does not modify or refresh Modbus connections.

  • Use add_modbus_signal and del_modbus_signal to manage Modbus entries.

  • Typically used after network setup or signal registration to confirm configuration integrity.

Example: Display all registered Modbus signals

#include "DRFLEx.h"
#include <iostream>
#include <thread>
#include <chrono>
using namespace std;
using namespace DRAFramework;

int main()
{
    CDRFLEx drfl;

    // Preconditions:
    // - Connection established (open_connection)
    // - Manual (Teach) mode active
    // - Modbus device configured via add_modbus_signal()

    LPMODBUS_DATA_LIST pList = drfl.query_modbus_data_list();
    if (pList) {
        cout << "-------------------------------------------\n";
        cout << "[MODBUS SIGNAL LIST]\n";
        cout << "Total Signals: " << pList->_iCount << endl;

        for (int i = 0; i < pList->_iCount; ++i) {
            auto& data = pList->_tModbusData[i];
            cout << "-------------------------------------------\n";
            cout << "Index       : " << i << endl;
            cout << "Name        : " << data._szName << endl;
            cout << "Address     : " << data._iAddress << endl;
            cout << "Type        : " << (data._iType == 0 ? "Input" : "Output") << endl;
            cout << "Value       : " << data._iValue << endl;
        }
        cout << "-------------------------------------------\n";
    } else {
        cout << "[Modbus] No registered Modbus signals found.\n";
    }

    return 0;
}

Tips

  • Use this function frequently during field device mapping or I/O verification.

  • When signal values are not updating, check Modbus master/slave configuration and wiring.

  • Combine with get_modbus_input and set_modbus_output for real-time testing.

  • Ideal for debugging Modbus network communication directly from the Teach mode without running full automation sequences.