READ_FLANGE_SERIAL_EX
This structure indicates whether received data is available in the Flange Serial buffer (extended version). Unlike READ_FLANGE_SERIAL, this version supports multiple ports (e.g., X1, X2).
BYTE# |
Field Name |
Data Type |
Value |
Remarks |
|---|---|---|---|---|
0 |
|
|
0~1 |
Data receive flag for each port |
Total size: 2 bytes
Defined in: DRFS.h
typedef struct _READ_FLANGE_SERIAL_EX
{
// check ready to read for multiple ports
unsigned char _bRecvFlag[2]; // 0: non-receive, 1: received
} READ_FLANGE_SERIAL_EX, *LPREAD_FLANGE_SERIAL_EX;
Note
_bRecvFlag[0]→ Port 0 (e.g., X1)_bRecvFlag[1]→ Port 1 (e.g., X2)Used when the robot flange supports multi-port serial communication.